Palo Alto Analysis

Smart Citizen Logo

Test details

Devices summary

Devices list
Device Blueprint Documentation Timezone Source
08019004 CSIC STATION Documentation Europe/Madrid API
08019043 CSIC STATION Documentation Europe/Madrid API
08019044 CSIC STATION Documentation Europe/Madrid API
14129 SCK 21 CO2 Documentation Europe/Madrid API
14133 SCK 21 CO2 Documentation Europe/Madrid API
43148003 CSIC STATION Documentation Europe/Madrid API
43171002 CSIC STATION Documentation Europe/Madrid API

Device information

Below is a description of each device, finding documentation and data sources.

Device 08019004
Channel Units Type (raw/processed) Algorithm Description
NO ug/m3 Raw n/a No description available
NO2 ug/m3 Raw n/a No description available
NOX ug/m3 Raw n/a No description available
PM_10 ug/m3 Raw n/a No description available

Device 08019043
Channel Units Type (raw/processed) Algorithm Description
CO mg/m3 Raw n/a No description available
NO ug/m3 Raw n/a No description available
NO2 ug/m3 Raw n/a No description available
NOX ug/m3 Raw n/a No description available
O3 ug/m3 Raw n/a No description available
PM_10 ug/m3 Raw n/a No description available
SO2 ug/m3 Raw n/a No description available

Device 08019044
Channel Units Type (raw/processed) Algorithm Description
CO mg/m3 Raw n/a No description available
NO ug/m3 Raw n/a No description available
NO2 ug/m3 Raw n/a No description available
NOX ug/m3 Raw n/a No description available
O3 ug/m3 Raw n/a No description available
PM_10 ug/m3 Raw n/a No description available
SO2 ug/m3 Raw n/a No description available

Device 14129
Channel Units Type (raw/processed) Algorithm Description
BATT % Raw n/a Device battery status
CCS811_ECO2 ppm Raw n/a Equivalent CO2
CCS811_VOCS ppb Raw n/a total Volatile Organics Compounds
HUM %rh Raw n/a Urban board humidity (SHT31)
LIGHT lux Raw n/a Urban board ambient light
NOISE_A dBA Raw n/a A-scale noise SPL
PM_1 ug/m3 Raw n/a PM1 measurement from PMS5003
PM_10 ug/m3 Raw n/a PM10 measurement from PMS5003
PM_25 ug/m3 Raw n/a PM2.5 measurement from PMS5003
PRESS kPa Raw n/a Atmospheric pressure
SCD30_TEMP degC Raw n/a External temperature (SCD30)
SCD30_HUM %rh Raw n/a External humidity (SCD30)
SCD30_CO2 ppm Raw n/a CO2 (SCD30)
TEMP degC Raw n/a Urban board temperature (SHT31)
CCS811_ECO2_CLEAN ppm Processed clean_ts eCO2 cleaned data
CCS811_VOCS_CLEAN ppb Processed clean_ts Volatile Organic Compounds cleaned data
PM_10_CLEAN ug/m3 Processed clean_ts PM10 calculated based on both PMS5003 PM10 inputs
PM_1_CLEAN ug/m3 Processed clean_ts PM1 calculated based on both PMS5003 PM10 inputs
PM_25_CLEAN ug/m3 Processed clean_ts PM2.5 calculated based on both PMS5003 PM2.5 inputs

Device 14133
Channel Units Type (raw/processed) Algorithm Description
BATT % Raw n/a Device battery status
CCS811_ECO2 ppm Raw n/a Equivalent CO2
CCS811_VOCS ppb Raw n/a total Volatile Organics Compounds
HUM %rh Raw n/a Urban board humidity (SHT31)
LIGHT lux Raw n/a Urban board ambient light
NOISE_A dBA Raw n/a A-scale noise SPL
PM_1 ug/m3 Raw n/a PM1 measurement from PMS5003
PM_10 ug/m3 Raw n/a PM10 measurement from PMS5003
PM_25 ug/m3 Raw n/a PM2.5 measurement from PMS5003
PRESS kPa Raw n/a Atmospheric pressure
SCD30_TEMP degC Raw n/a External temperature (SCD30)
SCD30_HUM %rh Raw n/a External humidity (SCD30)
SCD30_CO2 ppm Raw n/a CO2 (SCD30)
TEMP degC Raw n/a Urban board temperature (SHT31)
CCS811_ECO2_CLEAN ppm Processed clean_ts eCO2 cleaned data
CCS811_VOCS_CLEAN ppb Processed clean_ts Volatile Organic Compounds cleaned data
PM_10_CLEAN ug/m3 Processed clean_ts PM10 calculated based on both PMS5003 PM10 inputs
PM_1_CLEAN ug/m3 Processed clean_ts PM1 calculated based on both PMS5003 PM10 inputs
PM_25_CLEAN ug/m3 Processed clean_ts PM2.5 calculated based on both PMS5003 PM2.5 inputs
SCD30_CO2_COR Processed poly_ts

Device 43148003
Channel Units Type (raw/processed) Algorithm Description
NO ug/m3 Raw n/a No description available
NO2 ug/m3 Raw n/a No description available
NOX ug/m3 Raw n/a No description available
PM_10 ug/m3 Raw n/a No description available
PM_1 ug/m3 Raw n/a No description available
PM_25 ug/m3 Raw n/a No description available
SO2 ug/m3 Raw n/a No description available

Device 43171002
Channel Units Type (raw/processed) Algorithm Description
H2S ug/m3 Raw n/a No description available
NO ug/m3 Raw n/a No description available
NO2 ug/m3 Raw n/a No description available
NOX ug/m3 Raw n/a No description available
O3 ug/m3 Raw n/a No description available
PM_10 ug/m3 Raw n/a No description available
PM_1 ug/m3 Raw n/a No description available
PM_25 ug/m3 Raw n/a No description available
SO2 ug/m3 Raw n/a No description available

Analysis

Introducción

Este análisis realiza la comparativa del periodo de medidas desde el 28/05/2021 hasta el 01/10/2021 como primer tramo de dos unidades de medición de calidad de aire en el recinto de Palo Alto. Las unidades cuentan con medidores de PM (Partículas en suspensión), CO2, ruido, temperatura, humedad y presión barométrica. El primero de ellos se sitúa en la entrada del recinto (14129), mientras que el segundo se encuentra en el lateral de la Nave XYZ (14133). Ambos sensores se encuentran a una altura de aproximadamente 3m y están alimentados mediante panel solar.

Adicionalmente, se añaden al análisis estaciones de la Agencia de Salud Pública y la Generalitat de Cataluña, situadas en zonas de ciudad tales como el Eixample (estación urbana de tráfico), Gracia (estación urbana de tráfico), Poblenou (estación urbana de fondo), Vila-Seca (estación suburbana de fondo) y Tarragona (estación suburbana industrial).

La estaciones de Vila-Seca y Tarragona han sido seleccionadas únicamente como referencia para las comparaciones de las medidas de PM1 y PM2.5, ya que son las únicas comparables con las medidas de referencia de los Smart Citizen Kits instalados en Palo Alto. Ninguna estación de referencia cuenta con medidas de CO2 o ruido en exterior, por lo que esta comparativa se realiza a través de datos tabulados. Las medidas de PM10 no son utilizadas como referencia a pesar de encontrarse en todas las estaciones ya que el sensor de PM10 en el Smart Citizen Kit no presenta buena eficiencia en las medidas de este tamaño de partículas, por lo que no son comparables a las medidas oficiales.

Importante notar que los sensores de PM del Smart Citizen Kit no utilizan el mismo principio de funcionamiento que los usados en los instrumentos de referencia, por lo que el análisis aquí realizado únicamente debe servir como referencia sin validez científica.

Análisis Datos de Ruido

Los datos de ruido se encuentran representados en el gráfico inferior. Es posible hacer zoom en distintas partes del mismo para analizar más en detalle.

El nivel de ruido medio de cada medidor es de:


Estos niveles de ruido, en nivel promedio, son similares a aquellos que se pueden encontrar en un espacio de oficina tranquilo o una biblioteca (ref).

En el gráfico inferior se muestran datos de dispersión y comparativa día vs. noche en los datos de ruido del espacio para el sensor de la XYZ como ejemplo, aunque los datos son comparables en cada sensor. Debajo se muestran promedios de ruido en diferentes horarios:

Estos datos muestran una mayor actividad en la tarde, con valores más cercanos a los 50 dBA de media, aunque normalmente afectados en promedio por la presencia de eventos que ocurren en la tarde. Los valores nocturnos por el contrario son inferiores a 33 dBA, mostrando que la actividad de fondo del recinto es silenciosa, que denota ausencia de maquinaria, tráfico o similares.

Debajo se muestra el en ruido de los eventos (San Juan):

Y en la figura inferior se muestran datos de ruido centrados en otros eventos, donde los máximos a los 90dBA: